Burntstone
CERAMIC   LIMITED

Technical Data August 2006

Crucible furnaces
WM series crucible furnaces to 1200°C
Crucible furnace

 
  • 3 Standard sizes
  • Stationary or tilting bodies
  • Safe, simple and economical to use
  • Automatic control with indication
  • High efficiency, low thermal mass insulation
  • Over temperature protection
     

     

  • GENERAL DESCRIPTION:

    WM series crucible furnaces have an inner "heat box" surrounded by an air gap set in a steel outer casing. They are cylindrical in external and internal shape.

    The working insulation face is lightweight insulating firebrick for strength and wear resistance. This is backed with suitable fibre materials for maximum heat saving efficiency. At the bottom of the workspace a floor is provided with similar insulation to that in the sides.

    A sheathed thermocouple within the chamber gives accurate temperature sensing. The lift and turn lid covers the working area and the hot face insulation lining allowing obstruction-free access to the chamber where a standard crucible may be positioned.

    The electrical controls are mounted in a box to the side of the kiln case. Temperature control is achieved through a separate unit connected to the control box by a flexible cable and normally attached to the side of the kiln near the top for easy operation. The temperature controller incorporates thermocouple break protection as standard.

    A choice of PID digital controllers with digital setting and readout are offered. A safety switch is fitted to the lid in all models.  Various optional extras are available.

    ProductMax Temp°CInternal Dimensions (mm)VolumePower requirementWeight
    Diameter Height Litres kWVoltskg
    WM 70 1200 500 475 10 18 400 3ph, N, E 500
    WM 150 1200 600 480 20 20 400 3ph, N, E 800
    WM 300 1200 770 715 40 30 400 3ph, N, E 1000


    All kilns will operate on 415V 3ph, N, E, supply. Crucible furnaces can be supplied with fixed (bale-out) or tilting bodies.

    The above data is offered only as general performance characteristics and may alter due to mains voltage fluctuations and modifications etc. Dimensions are in mms.

    The information and data herein are offered solely for your consideration and guidance and are not to be construed as a warranty or specification. Nothing contained herein is to be interpreted as authorisation to practice a patented invention without a licence.
    E-mail us
    E-mail us
    Thermal Insulation Dryers Refractories
    Applications
    Guidance
    Annealing furnaces,
    & ovens
    New furnaces
    Used furnaces, kilns
    & ovens summary
    Home
    Used ovens
    Environmental
    Used ovens - Drying Used ovens - Annealing
    Used furnaces - Low temp. Used furnaces - Medium temp. Used furnaces - High temp.